Topic 3: Electric Circuits: 39. be able to use the equation R = ρl/A
The equation R = ρl/A links a conductor's resistance R (in ohms, Ω) to the resistivity ρ of its material (in ohm metres, Ω m), its length l (in metres, m) and its cross-sectional area A (in square…
- Point 8 of 16
Study notes
From the teaching notes for this specification point.
The idea
The equation R = ρl/A links a conductor's resistance R (in ohms, Ω) to the resistivity ρ of its material (in ohm metres, Ω m), its length l (in metres, m) and its cross-sectional area A (in square metres, m²). Resistivity is a property of the material; resistance also depends on the sample's geometry. Longer or thinner conductors have greater resistance, so doubling l doubles R while doubling A halves R. Rearrange to ρ = RA/l when finding resistivity, or to A = ρl/R when sizing a wire. Work in SI units: convert mm² to m² by multiplying by 10⁻⁶, and cm to m by multiplying by 10⁻². For a wire of diameter d, A = πd²/4. Typical exam task: a copper wire of resistivity 1.7 × 10⁻⁸ Ω m, length 2.0 m and area 1.0 × 10⁻⁶ m² gives R = (1.7 × 10⁻⁸ × 2.0)/(1.0 × 10⁻⁶) = 0.034 Ω.
What earns the marks
- States R = ρl/A and identifies ρ as resistivity in Ω m, l as length in m and A as cross-sectional area in m².
- Recognises that resistance rises with length and falls with area, because resistivity is a material property independent of geometry.
- Rearranges correctly, for example ρ = RA/l or A = ρl/R, before substituting values.
- Converts units correctly, for example mm² to m² using a factor of 10⁻⁶, and cm to m using 10⁻².
- Calculates cross-sectional area from a diameter using A = πd²/4 when the diameter rather than the area is given.
- Substitutes consistently in SI units and gives the answer with the correct unit (Ω for resistance, Ω m for resistivity).
Common mistakes and how to put them right
Using the diameter directly as the area.
Put it right: Compute A = πd²/4 from the diameter, or use the radius with A = πr².
Forgetting to convert mm² to m².
Put it right: Multiply the value in mm² by 10⁻⁶ to obtain m².
Treating resistivity as changing with the wire's length.
Put it right: Resistivity is a material property, while resistance depends on both material and geometry.
Inverting the ratio, for example multiplying by A and dividing by l.
Put it right: Check the rearrangement R = ρl/A gives larger R for longer, thinner wires.
Exam tips
- Write the equation, rearrange symbolically, then substitute numbers, so unit slips are easier to spot.
- Convert every quantity to SI base units before calculating, and state the unit of the final answer.
- Sanity-check the magnitude: a short, thick metal wire should have a small resistance, typically a fraction of an ohm.
Try the lesson
The start of the Topic 3: Electric Circuits: 39. be able to use the equation R = ρl/A lesson, made from teaching notes for this specification point.
Have a go first
A copper wire has length 2.0 m and uniform cross-sectional area 1.0 × 10⁻⁶ m². The resistivity of copper is 1.7 × 10⁻⁸ Ω m. Calculate the resistance of the wire.
There is more to this lesson
The full lesson goes on to check your understanding and help you earn the marks. Create a free account to carry on, with your progress saved.
A week of Premium from your first lesson · Then the free plan continues · No card, no charge
Test your understanding of Topic 3: Electric Circuits: 39. be able to use the equation R = ρl/A
Active recall beats re-reading. Take an instant quiz now to test what you’ve learned and lock it into long-term memory.
A week of Premium from your first lesson · Then the free plan continues · No card, no charge